General specifications:
RDS signal Conforming to EBU
Doc Teah. 3244 -E and CENELEC PrEN50067 spec. Coding Differential and
Biphase Modulation DSB with suppressed carrier Frequency 57 kHz Bandwidth
± 2.4 kHz RDS injection into MPX signal < –16dB RDS signal
output level 0 dBu Phase 90° or 0 with respect to the 19 kHz pilot
signal Noise - 92 dBm DIN AUDIO 0 dBm
ATTENTION: All cables should not be more than 3 meters length.
Inputs:
Pilot Reference Input 1 Vpp (Pilot
19 kHz; sine wave) Input impedance 19KHz >100 KW Inputs +10 dBm (MPX
max; For the hookup in phase of the 19 kHz) Input impedance MPX 10 KW
Connectors BNC grouded to chassis
Outputs:
MPX + RDS output unbalanced,
AC coupled Output impedance 100 W (MAX Load 5kW) Amplitude response (MPX
TRANSIT) 2 Hz - 100 kHz ± 0.1 dB Connector BNC grouded to chassis
Data synchronization:
Serial interface (rear panel) RS 232-C asynchronous
(DB9) Data Input Full Duplex Format Selectable between 2400 and 19200
baud Connector 9 pin Subminiature Cannon female
Hardware electrical specifications:
Control Microprocessor RAM 128 kbyte
(Non volatile RAM data retention 10 years) Power supply 113 /230 V ac
50/60 Hz (internal selectable) Power consumption 4 VA
Operating conditions:
Operating temperature 0 to 50 °C
Mechanical specifications:
Weight
2.5 kg Dimensions (W x H x D) 483 x 44.5 x 240 mm
Remote I/O:
MS, TA,
RDS OFF CMOS Level Connector 25 contact subminiature cannon female